KUET Institutional Repository

Lightning Surge Analysis And Protection System Design For Typical Mobile Phone Tower

Show simple item record

dc.contributor.advisor Yusuf, Dr. Md. Salah Uddin
dc.contributor.author Islam, Md. Zoyheroul
dc.date.accessioned 2018-05-16T11:13:20Z
dc.date.available 2018-05-16T11:13:20Z
dc.date.copyright 2018
dc.date.issued 2018-04
dc.identifier.other ID 1503560
dc.identifier.other Khulna University of Engineering & Technology (KUET) thesis/dissertation/internship reports are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission.
dc.identifier.uri http://hdl.handle.net/20.500.12228/90
dc.description This thesis report submitted to the department of Electrical and Electronic Engineering in partial fulfillment of the degree of Master of Science in Electrical and Electronic Engineering, April 2018 en_US
dc.description Cataloged from PDF Version of Thesis.
dc.description Includes bibliographical references (pages 59-62).
dc.description.abstract Lightning is not only a serious weather hazard but also it has fascinated and excited humans for as long as they have watched the skies. It has been estimated that the earth is struck by 100 lightning bolts every second. Now a days lightning hazard is an important issue of major interest for the engineers and architects while designing the electric equipment & tall structures. Analyses of lightning surge characteristics deserve much more importance for designing protection scheme for communication tower against lightning. If a return stroke hit upon any metallic structure such as communication tower suited on multi-storied building’s roof, the lightning transient over voltage will propagate through the columns, beams and other metallic structures of the building. If proper protection is not provided against lightning, the building, electric equipment and also human being living inside the building will be affected. Obviously this matter has been deserving much more attention for public safety. Modern power and communication system includes many electronic appliances for controlling and information processing purpose. It is essential to operate communication systems utilizing these electronic appliances. In this research the lightning surge response e.g, nature of voltage, current, surge impedance, electric field distribution and effect of direct stroke in another word the lightning surge characteristics on the multi-storied building and communication tower have been analysed. Induced effect of direct stroke on electronic equipment inside the building on different floors has also been analysed. Two different methods are used to analyzed the surge characteristics. Firstly Numerical Electromagnetic Code (NEC-2) is used as simulation tool for finding the surge response. Secondly ATP Draw (Alternative Transient Program) has been used for finding the surge characteristics. In this research IEEE model, Pinceti model and Fernandes-Diaz model of MOV type surge arrester are simulated with ATP-EMTP modified their parameters to determine the optimum values for designing proper protection scheme for the typical mobile phone towers. en_US
dc.description.statementofresponsibility Md. Zoyheroul Islam
dc.format.extent 62 pages
dc.language.iso en_US en_US
dc.publisher Khulna University of Engineering & Technology (KUET), Khulna, Bangladesh. en_US
dc.subject Wireless Networks en_US
dc.subject Communication Towers en_US
dc.subject Mobile Phone Network en_US
dc.subject Networking
dc.title Lightning Surge Analysis And Protection System Design For Typical Mobile Phone Tower en_US
dc.type Thesis en_US
dc.description.degree Master of Science in Electrical and Electronic Engineering
dc.contributor.department Department of Electrical and Electronic Engineering


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search KUET IR


Browse

My Account

Statistics