dc.contributor.advisor |
Yousuf, Prof. Dr. Mohammad Abu |
|
dc.contributor.author |
Khan, Md. Muzahedul Islam |
|
dc.date.accessioned |
2018-05-21T06:18:29Z |
|
dc.date.available |
2018-05-21T06:18:29Z |
|
dc.date.copyright |
2017 |
|
dc.date.issued |
2017-03 |
|
dc.identifier.other |
ID 1553558 |
|
dc.identifier.uri |
http://hdl.handle.net/20.500.12228/141 |
|
dc.description |
This thesis is submitted to the Department of Chemistry, Khulna University of Engineering & Technology in partial fulfillment of the requirements for the degree of Master of Science in Chemistry, March 2017. |
en_US |
dc.description |
Cataloged from PDF Version of Thesis. |
|
dc.description |
Includes bibliographical references (pages 170-178) |
|
dc.description.abstract |
A facile and low-cost electrochemical technique for the detection of phenolic isomers
(PIs), hydroquinone (HQ), catechol (CC), and resorcinol (RS), in aqueous system was
developed. In this research, graphite based electrode (GBE) fabricated from a regular HB pencil (Brand: Faber Castell). HB pencil collected from the local stationary shop was used for fabricating working electrode termed as HB pencil electrode (HBPE) in the
experiment. Then HBPE was also modified electrochemically by amino acid (AA),
namely Glycine (GLY) and Aspartic Acid (ASA). Modified electrodes were termed as
GLY-HB and ASA-HB in total working process. HBPE, GLY-HB and ASA-HB
electrodes were used in detection of PIs by CV and DPV. The bare HBPE showed good
electroanalytical activity effect on the redox reaction towards PIs. Both GLY-HB and
ASA-HB electrodes showed catalytic activity on the redox reaction to PIs over HBPE. A
series of pH dependent reactions were performed in phosphate buffer solution (PBS) and total analyses and detection processes were continued at pH 6.8 which was used as the supporting electrolyte. The influences of scan rate and concentration on the redox behavior of HQ, CC and RS in both GLY-HB and ASA-HB were discussed. The anodic peak current versus the concentration of HQ, CC and RS showed a linear relationship. The variation of peak current was also plotted with Square root of scan rate. The
electrochemical processes were diffusion controlled in all cases. The constructed
electrodes produced reproducible and stable results in all cases.
The limit of detection (LOD) was calculated by signal-to-noise ratio (S/N) = 3. In
simultaneous detection, the LOD for HQ, CC and RS at bare HBPE were 12.473 μML-1,
16.132 μML-1 and 25.25 μML-1, respectively. The sensitivity for HQ, CC and RS is
470.481 μA/mM/cm2, 363.781 μA/mM/cm2 and 232.416 μA/mM/cm2, respectively at bare
HBPE. LOD for HQ, CC and RS at GLY-HB were 5.498 μML-1, 7.119 μML-1 and 14.794
μML-1, respectively and those were 22.459 μML-1, 25.478 μML-1 and 38.303 μML-1,
respectively at ASA-HB in simultaneous detection. The sensitivity for HQ, CC and RS is
364.785 μA/mM/cm2, 282.712 μA/mM/cm2 and 135.560 μA/mM/cm2, respectively at
GLY-HB and 374.483 μA/mM/cm2, 330.108 μA/mM/cm2 and 219.574 μA/mM/cm2,
respectively at ASA-HB in simultaneous detection.
Cost of one HBPE is about 5.00 BDT, one GLY-HB or ASA-HB electrode is about 7.00
BDT while one glassy carbon (GC) electrode is 14,000.00 BDT. So HBPE is at least 2800 times and that for GLY-HB or ASA-HB electrode is 2000 times cheaper than conventional commercial GC electrodes. |
en_US |
dc.description.statementofresponsibility |
Md. Muzahedul Islam Khan |
|
dc.format.extent |
178 pages |
|
dc.language.iso |
en_US |
en_US |
dc.publisher |
Khulna University of Engineering & Technology (KUET), Khulna, Bangladesh |
en_US |
dc.rights |
Khulna University of Engineering & Technology (KUET) thesis/dissertation/internship reports are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. |
|
dc.subject |
Phenolic isomers |
en_US |
dc.subject |
Graphite Based Electrode |
en_US |
dc.subject |
Isomers |
en_US |
dc.subject |
Electrodes |
en_US |
dc.title |
Cost Effective Graphite Based Sensor for Simultaneous Detection of Phenolic Isomers |
en_US |
dc.type |
Thesis |
en_US |
dc.description.degree |
Master of Science in Chemistry |
|
dc.contributor.department |
Department of Chemistry |
|