dc.contributor.advisor |
Jamal, Dr. A.B.M. Mamun |
|
dc.contributor.author |
Akhter, Irani |
|
dc.date.accessioned |
2018-05-21T08:55:44Z |
|
dc.date.available |
2018-05-21T08:55:44Z |
|
dc.date.copyright |
2017 |
|
dc.date.issued |
2017-04 |
|
dc.identifier.other |
ID 0000000 |
|
dc.identifier.uri |
http://hdl.handle.net/20.500.12228/147 |
|
dc.description |
This thesis is submitted to the Department of Chemistry, Khulna University of Engineering & Technology in partial fulfillment of the requirements for the degree of Master of Science in Chemistry, April 2017. |
en_US |
dc.description |
Cataloged from PDF Version of Thesis. |
|
dc.description |
Includes bibliographical references (pages 88-100) |
|
dc.description.abstract |
In biological and environmental applications, pH is an important parameter that needs to
monitor in regular basis. Conventionally, the measurement processes take a considerable
amount of time involving several calibration steps and handling of fragile electrodes. In
this work, we propose a new, robust and reliable way of sensing pH. The sensor has been
fabricated based on tungsten oxide nanoparticle modified glassy carbon electrode
(WO3/GCE). WO3 is a promising material for pH sensor because of its availability,
stability, good morphological and structural control of the synthesized nanostructures.
In this work, hydrothermal synthesis method was used for the fabrication of
WO3 nanoparticles. For the fabrication of the pH sensor, the nanoparticles were mixed
with Nafion and chitosan before drop coating onto the GCE surface. Scanning electron
microscopy (SEM), x-ray diffraction (XRD), energy dispersive x-ray spectroscopy (EDX)
and Raman spectroscopy were used to characterize the nanoparticle. Cyclic voltammetry
(CV), zero current potentiommetry (OCP) and square wave voltammetry (SWV) were
used to monitor the potential shift based on different pH in the buffer solutions. This
electrochemical pH sensor showed a sensitivity of 60 mVpH-1 and a potential drift of 2.4 –
5.0 % after three hours of continuous use. The sensor showed linearity range of pH 3 -11
and could retain 95% of its initial activity after 1 week of use. The electrode was found to
respond both in the presence and absence of oxygen, further expanding the potential
applications to include de-oxygenated environments. The WO3 based sensor showed good
sensitivity and long term stability, which would be a potential platform to develop a low
cost pH sensor for a wider range of applications. |
en_US |
dc.description.statementofresponsibility |
Irani Akhter |
|
dc.format.extent |
100 pages |
|
dc.language.iso |
en_US |
en_US |
dc.publisher |
Khulna University of Engineering & Technology (KUET), Khulna, Bangladesh |
en_US |
dc.rights |
Khulna University of Engineering & Technology (KUET) thesis/dissertation/internship reports are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. |
|
dc.subject |
pH |
en_US |
dc.subject |
pH Sensor |
en_US |
dc.subject |
Electrochemical Methods |
en_US |
dc.subject |
Tungsten Oxide (WO3) |
en_US |
dc.subject |
Tungsten Oxide (WO3) Nanoparticle |
en_US |
dc.title |
Development of Novel pH Sensor Based on Nanoparticle Modified Electrochemical Sensing Platform |
en_US |
dc.type |
Thesis |
en_US |
dc.description.degree |
Master of Science in Chemistry |
|
dc.contributor.department |
Department of Chemistry |
|