dc.description.abstract |
The nanostructures of metal oxides are attractive and important for nanosensor research in
the broad range of applications in various fields of biological, environmental and
analytical chemistry. Due to their potential applications and special properties metal
oxides nanoparticle have concerned considerable attention which are strongly related with
their size, structure and morphology. Among the metal oxide, cupric oxide (CuO) is
found to be one of the most popular oxide. Owing to its exceptional electrochemical
activity and the possibility of promoting electron transfer at a low potential, availability,
stability, good morphological and structural control of the synthesized nanostructures,
CuO
is a good candidate for pH sensing application.
In this paper, an electrochemical pH sensor that has been fabricated using copper oxide
modified glassy carbon electrode (CuO/GCE). The difference in peak potential shift while
using CuO/GCE as pH sensor was measured using square wave voltammetry (SWV); and
was found to be linear over the range of pH 3-9, with a sensitivity of
60
mVpl-f'. The
sensor shows a potential drift of 1.97 —3.33 % after three hours of continuous use; and
could retain
95% of its initial sensitivity after 1 week of use. The electrode was found to
respond both in the presence and absence of oxygen, further expanding the potential
applications to include it
into de-oxygenated environments. This prototype has been
tested in real samples and verified by using commercial pH meter. The CuO based sensor
showed good sensitivity and long term stability that may show the way to develop a low
cost solid state pH sensor for a wider range of applications. |
en_US |
dc.description.statementofresponsibility |
Sanzida Mohosina Toma |
|
dc.format.extent |
108 pages |
|
dc.language.iso |
en_US |
en_US |
dc.publisher |
Khulna University of Engineering & Technology (KUET), Khulna, Bangladesh |
en_US |
dc.rights |
Khulna University of Engineering & Technology (KUET) thesis/dissertation/internship reports are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. |
|
dc.subject |
pH Sensor |
en_US |
dc.subject |
Nanoparticle |
en_US |
dc.title |
Fabrication of a pH Sensor Based on Metal Oxide Nanoparticle and Ion Exchanging Surfaces |
en_US |
dc.type |
Thesis |
en_US |
dc.description.degree |
Master of Science in Chemistry |
|
dc.contributor.department |
Department of Chemistry |
|